Broadcast Tools, Inc.
DSC-20, Dual Satellite Receiver Controller Set-up guide
INSTALLATION Continued
Serial burst mode programming
The Serial BURST mode data format is as follows: *PRMM<cr>
Pxxxxxxxx = OPTIONAL Password (ID).
* = Indicates burst mode.
P = Recvr Port Number 1 or 2.
R = Receiver Type: <V> for Variable (StarGuide II and/or III,
Wegener Unity 4000)
MM = Channel number.
<cr> = Carriage return, End of string. (DO-IT)
Examples w / No Password:
*1V01<cr> Selects Variable (StarGuide II and/or III,
Wegener Unity 4000) 01 on Recvr port # 1
*2V01<cr> Selects Variable (StarGuide II and/or III,
Wegener Unity 4000) 01 on Recvr port # 2
*1V20<cr> Selects Variable (StarGuide II and/or III,
Wegener Unity 4000) 20 on Recvr port # 1
*2V20<cr> Selects Variable (StarGuide II and/or III,
Wegener Unity 4000) 20 on Recvr port # 2
Examples w / Password:
P1234*2V01<cr> Selects Variable (StarGuide II
and/or III, Wegener Unity 4000) 01 on Recvr port # 2