Wegener 4422 Manual de instrucciones Pagina 56

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 55
Page 56
UTY4422-002 Page 56 of 72
R E T U R N
P r e s s < S E L E C T >
Moves to second level screen MPEG Status.
B.5.4 Settings Table
S E T T I N G S T A B L E
P r e s s < S E L E C T >
Pressing <SELECT> allows for display of all valid Settings Table entries, including “Last
Acquired” carrier and “Last Requested” carrier settings. Each setting is displayed as a pair of
screens. Scroll through each pair and from pair-to-pair with the right/left arrow keys.
P O R T : n R A T E : d d . d d d
P R O G : x x x x x y y y
PORT: n is ASI Input Port Number’
RATE: dd.ddd is Data Rate in Mbps,
PROG: xxxxx is the Program Number, an up-to-5-digit number which, in the PAT, points to the
PID for a particular service’s PMT.
ENTRY: yyy is ACQ (Last acquired), REQ (Last requested), or a Table Entry Number 1 - 48.
R E T U R N
P r e s s < S E L E C T >
Moves back to second level, SETTINGS TABLE, screen.
B.5.5 NC Status
N C S T A T U S
P r e s s S e l e c t
Moves to third level screen.
S / N : n n n n n n s s s s s s s s
C O M P E L : c c c c c c c c c c c c
S/N: nnnnnn is the unit serial number,
LOCK STATUS: ssssssss is the COMPEL lock status,
COMPEL CONTROL REQUIREMENT: cc…cc is REQUIRED or NOT REQUIRED.
L O C A L C T R L : x x x x x x x x